Three recently commissioned projects are worth reading together: they cover onshore wind, offshore wind and a fixed tall structure — and each tests a different capability of the same technology: full-structure charge compensation, a certified system-level delivery path, and long-term data that a third party can check.

Qinzhou: the first onshore turbine with full-structure charge compensation

The first onshore wind turbine in China to be fitted with a CMCE system has been commissioned at Qinzhou. The point the public report emphasises is "full-structure charge compensation": not a single device on the tower top, but tower, nacelle, blades and foundation brought into one charge-drainage path. Monitored discharge current during operation was recorded in the 3,000–4,000 mA range.

That magnitude deserves a note. Under a conventional air-terminal scheme a strike current is measured in tens of kiloamperes, and the down conductor and earthing have to survive it. A compensating scheme drains charge continuously and slowly instead, so the current is small and sustained — milliamps to a few amps over time rather than one impulse.

6.5 MW offshore unit: the first deployment of a DNV-certified scheme

China's first 6.5 MW offshore wind turbine carrying a CMCE protection system has completed installation; the scheme had previously obtained DNV independent engineering certification. Site monitoring reported the system running well, with electrical and protection parameters meeting and in places exceeding design expectations.

For offshore wind the real significance is that the delivery path has been proven: design, certification documentation, installation and operation monitoring now form a repeatable process. Offshore units are hard to reach and expensive to service, so retrofits after a failure are never economic.

Hong Kong: two years of strike data around an observation tower

A tower at Ocean Park, Hong Kong, has now run two full years with a CMCE 120 installed. The project team purchased the latest lightning location data from the Hong Kong Observatory and counted cloud-to-ground (C-G) records within a 500 m radius of the tower.

ItemValue
Search radius500 m
PeriodTwo years after installation of the CMCE 120
C-G strikes recorded15
Largest strike current-60 kA
Smallest strike current-3 kA
Strike locationsAll outside the 120 m protection radius

According to the published summary, all 15 strikes fell outside the declared 120 m radius. For a fixed tower, the value of this dataset is not the vague claim "two years without a strike", but that it produces third-party location records from the Observatory's network rather than a vendor's own account.

What the three datasets show

  • Scenario coverage: onshore wind, offshore wind and a fixed tower — three mounting conditions and three earthing conditions, all working.
  • Checkability: the tower data uses an independent lightning location network, the most persuasive form of evidence in acceptance and insurance discussions.
  • Delivery path: the 6.5 MW project links DNV certification, installation and monitoring into one chain that can be repeated on similar offshore projects.

A caution: these figures come from the project owners and public reporting. The exact methodology — network accuracy, event filtering rules and the time window — should be taken from the original records; when quoting them for a design comparison or acceptance, ask for the raw dataset as well.

Related reading

For the working principle and standards comparison see how field-compensating protection works; for farm layout and shadowing see wind and solar farm lightning protection. To have a layout checked for a specific project, submit your requirement here or write to sales@malinsmarine.com.

Source: public reports on the Futurewa news centre (futurewa.com). This page is a rewritten summary for technical reference.