A vessel on open water has nothing to shelter behind: the mast, radome and superstructure are usually the highest points for miles. A single strike can damage the mast structure, destroy navigation and communication electronics, and delay a port call — for a working ship the last item is often the most expensive.

Assess first, select second

The first task in marine lightning protection is not choosing a device, but establishing which point must be protected and how large the coverage radius has to be. The inputs are: height of the mast or antenna mast above the waterline, plan dimensions of the superstructure, whether the rig or rigging is carbon, where the navigation electronics (VHF, AIS, radar, GNSS) sit, and the hull material — steel, aluminium, GRP or composite.

On the standards side, marine work usually follows the risk-assessment approach of IEC 62305 while also satisfying class society and flag-state requirements. In practice the working rule is simple: protection radius must be at least the distance from the highest point to the furthest item being protected.

Two technical routes

A conventional air terminal takes the strike at the masthead and routes current down to a sea earth. It is inexpensive and well codified, but it accepts that a strike will occur. For yachts and workboats that operate in thunderstorm areas, suppression is increasingly preferred: no strike forms inside the protected volume, so neither the rig nor the electronics has to carry strike current or absorb its induced overvoltage.

The CMCE marine range scales with hull size: GOLD (small, 1.065 kg), PLATINUM (medium, 2.75 kg) and DIAMOND (large, 6.17 kg). The weight difference drives masthead loading and mounting detail, which is why selection logic differs between a small sailing yacht and a merchant vessel.

Where to mount it

  • Above what you protect. The device sits at the masthead or on a dedicated spar so the protected sphere covers the mast, radome and bridge top completely.
  • Avoid shadowing. If a taller structure — a crane, a funnel — stands nearby, parts of the vessel can fall outside the protected volume. Check it on the drawing and add a point or a local air-termination mesh where needed.
  • Keep electronics electrically continuous. Bond mast, antenna bases and metallic superstructure parts so no potential difference can develop between them during a strike or from static.
  • Keep the discharge path short. Conductors should be short, direct and routed away from sensitive signal cables, terminating reliably at the hull earth or a sea earth plate.

Earthing and bonding: half the result

A compensating device drains induced charge to earth; if the vessel's earthing is discontinuous, performance suffers. A steel hull is itself an excellent earth. GRP and composite hulls need a dedicated earth plate or immersed electrode. Bonding should cover mast, superstructure, steering gear and the casings of major electrical equipment. For distribution and signal circuits, surge protective devices selected along the lines of IEC 62305-4 complete the picture: suppression outside, limiting inside.

Verifying it in service

Inspection is straightforward: visual condition and fastening, integrity of connecting conductors, earth resistance, and corrosion at the masthead. Where traceable records are needed, a Storm 7 monitoring system logs field activity and events in the protected area; export the data at each port call and you have evidence for maintenance files and insurers.

What to send the yard or designer

Three documents move a project forward: the vessel arrangement drawing with mast height and superstructure outline, the list of navigation and communication equipment with positions, and a note on hull material and earthing arrangement. From those we return a device layout, model selection and mounting accessory list. Send drawings and requirements here, or write to sales@malinsmarine.com.